Subscribe

Reply to the letter to the editor

DOI: 10.4244/EIJ-D-25-00890

Reply: Transcatheter aortic valve implantation and covert brain injury: does silence equal reassurance?

Victor Alfonso Jimenez Diaz1,2, MD, MPH; Pablo Juan Salvadores2, PhD; Paula Bellas Lamas2,3, MD; on behalf of the AUREA investigators

We sincerely thank Dr Pyrpyris and colleagues for their thoughtful comments1 regarding our recent publication, the AUREA trial2. We fully agree with their perspective on the complex and multifactorial nature of cerebral microembolism during transcatheter aortic valve implantation (TAVI) procedures. Despite significant procedural advances, the cerebral impact of microembolic events, often silent, remains a major concern, particularly in elderly patients already at risk of cognitive impairment. In line with the authors’ comments, we emphasise the critical need to identify novel and reliable biomarkers of cerebral microembolism after TAVI. Current approaches to detect brain injury, including magnetic resonance imaging (MRI), though highly sensitive, are not always practical in daily clinical settings due to availability, cost, and patient frailty. Developing blood biomarkers such as glial fibrillary acidic protein, neurofilament light chain, tau and its peptides, and β-synuclein3 that are not only sensitive and specific but also easy to use and interpret could greatly enhance early detection, monitoring, and risk stratification of patients undergoing TAVI, as well as prediction of complications and clinical outcomes at follow-up. In addition, artificial intelligence-enhanced imaging enables accurate quantification of vascular and valvular calcium burden4. Beyond improving procedural planning, it may allow identification of patients at highest embolic risk and support tailored neuroprotective strategies. Equally important is the implementation of standardised neurocognitive assessments before and after the procedure. Cognitive outcomes after TAVI are variable and may depend on multiple factors, including baseline status, cerebral perfusion changes, embolic burden, and systemic inflammation. Objective neurological testing, both clinical and through validated cognitive questionnaires, should be routinely incorporated in TAVI trials and, when feasible, in clinical practice5. This would allow more accurate characterisation of cognitive trajectories and identification of patients at risk of deterioration or, conversely, those likely to experience neurocognitive improvement. We also fully agree on the potential role of cerebral embolic protection devices (CEPDs). Although current evidence on clinical outcomes remains mixed, these devices consistently demonstrate their potential to reduce cerebral lesion volume and embolic burden6. The integration of CEPDs in TAVI, especially in selected high-risk patients or as part of comparative strategy trials (ClinicalTrials.gov: NCT05873816, NCT03130491), may prove beneficial in minimising microembolisation and its consequences7. Furthermore, combining CEPDs with refined antithrombotic approaches could offer synergistic protection and deserves exploration. Finally, as the authors mention, the identification of pharmacological strategies targeting both thrombotic and inflammatory pathways post-TAVI is a promising avenue. The interplay between prosthetic material, residual native leaflets, and flow dynamics can trigger proinflammatory and prothrombotic cascades, potentially leading to leaflet thrombosis and cerebral embolisation. Recent results with colchicine are promising, although they should be interpreted with caution given the reported increased risk of stroke in treated patients8. Further studies evaluating combinations of antiplatelet agents (ClinicalTrials.gov: NCT05283356), anticoagulants, and anti-inflammatory therapies (NCT06076824) are warranted to define optimal post-TAVI regimens that balance ischaemic, embolic, bleeding, and cognitive risks. In conclusion, the prevention and understanding of covert brain injury in the TAVI population must become a multidimensional effort: identifying feasible biomarkers, integrating neurocognitive assessment, evaluating device-based protection, and refining pharmacological strategies.

Funding

The AUREA trial is sponsored by the Spanish Ministry of Health, Consumer Affairs and Social Welfare call for innovative medicines, EC11-193, and complemented by the Galician Innovation Agency (Axencia Galega de Innovación - GAIN) through programme code IN607B-2021/18. Both have had no role in the design or execution of the trial nor in the analysis of the data. There is no industry involvement in the trial. ClinicalTrials.gov: NCT01642134. EudraCT: 2011-005784-24.

Conflict of interest statement

The authors have no conflicts of interest to declare regarding this manuscript.


References

Volume 21 Number 22
Nov 14, 2025
Volume 21 Number 22
View full issue


Key metrics

Suggested by Cory

Editorial

10.4244/EIJ-E-25-00027 Jul 7, 2025
Antithrombotic strategies after TAVI in light of cerebral microembolism
Dangas G and Nicolas J
free

Letter to the editor

10.4244/EIJ-D-25-00842 Nov 14, 2025
Letter: Transcatheter aortic valve implantation and covert brain injury: does silence equal reassurance?
Pyrpyris N et al
free

EXPERT REVIEW

10.4244/EIJ-D-18-00454 Sep 7, 2018
TAVI and the brain: update on definitions, evidence of neuroprotection and adjunctive pharmacotherapy
Lansky AJ et al
free

Expert Review

10.4244/EIJ-D-23-01087 Jul 1, 2024
Cerebrovascular events after transcatheter aortic valve implantation
Reddy P et al
free

10.4244/EIJV9SSA9 Sep 15, 2013
Antithrombotic and antiplatelet therapy in TAVI patients: a fallow field?
Collet J and Montalescot G
free

10.4244/EIJV8SQA11 Sep 30, 2012
Transcatheter aortic valve implantation and cerebrovascular accidents
Stortecky S et al
free

10.4244/EIJV8I1A4 May 15, 2012
Embolic protection devices during TAVI – the “proof of the pudding”
Van Mieghem NM and Serruys PW
free

10.4244/EIJV11SWA28 Sep 17, 2015
Antithrombotic therapy in TAVI patients: changing concepts
Gargiulo G et al
free

CLINICAL RESEARCH

10.4244/EIJV12I4A84 Jul 20, 2016
Filter-based cerebral embolic protection with transcatheter aortic valve implantation: the randomised MISTRAL-C trial
Van Mieghem NM et al
free
Chat with Cory
Hello , I'm Cory and I will do my best to answer your questions about this article. Please remember that this is an experimental feature, and that I'm still learning.
What are the funding sources and conflicts of interest related to the AUREA trial?
What are the key ischemic, embolic, bleeding, and cognitive risks associated with post-TAVI regimens?
How can optimal post-TAVI regimens be defined to balance these risks?
What are the potential future directions for research in this area?
X

PCR
Impact factor: 9.5
2024 Journal Citation Reports®
Science Edition (Clarivate Analytics, 2025)
Online ISSN 1969-6213 - Print ISSN 1774-024X
© 2005-2025 Europa Group - All rights reserved